Common parameter settings for Emerson EV1000 series frequency converters

Author: zhddq
Published on: 2025-04-24
Category: Industry News

function code

name

Setting Range

Minimum Unit

Factory settings

change

F000

Frequency given channel selection

O: Number given, LED keyboard display unit ⋀, V adjustment

1: Number given 2, terminal UP/DN adjustment

2: Number given 3, serial port given

3:  VCI simulation given (VCIL-GND)

4:  CCI simulation given (CCIGND)

5: Terminal Pulse (PULSE) Given

6: LED keyboard display unit potentiometer given

1

0

F101

Given channel gain

0.00~9.99

0.01

2

F002

Given the operating frequency number

Lower limit frequency (F013)~upper limit frequency (F012)

0.01HZ

50HZ

F003

Select the command channel for running)

0: LED keyboard display unit running command channel

1: Terminal operation command channel

2: Serial port operation command channel

1

0

F004

Setting the direction of operation

0: Forward 1: Reverse

1

0

X

F005

Maximum Output Frequency

Max (50.00, upper frequency limit)~650.0Hz

0.01HZ

50.00HZ

X

F006

Basic operating frequency

 1.00~650.0Hz

0.01HZ

50.00HZ

F008

reserve

 

 

 

F009

Torque boost

0.0 (automatic)

0.1%~30.0%

0.1%

0.0

F010

acceleration time

0.1~3600S

0.1S

20.0S

F011

Deceleration Time

0.1~3600S

0.1S

20.0S

F712

Relay output function selection

15: Inverter operation preparation completed (RDY)

1

15

X

F729

Selection of Analog Output Range

LED position: AO1 Convenience Selection

0: 0~10V or 0~20mA

1:  2~10V or 4~20mA

LED position: AO2 Convenience Selection

0 0~10V or 0~20mA

1:  2~10V or 4~20mA

1

00

F730

AO1 output gain

0.0~200.0%

0.1%

50.0%

F731

AO2 output gain

0.0~200.0%

0.1%

50.0%

FF01

Local address

0~126 127 is the broadcast address

1

1

X

FH00

Number of motors

2~14

2

4

X

FH01

Motor rated power

0.4~999.9kW

0.1KW

Model determination

X

FH02

Rated current of motor

0.1~999.9A

0.1A

Model determination

X

FL00

Selection of motor overload protection mode

0: No action

1: Ordinary motor (with low-speed compensation)

2: Variable frequency motor (without low-speed compensation)

1

1

X

FL01

Overload protection coefficient of motor

20.0~110.0%

0.1%

100%

X

FP01

Parameter write protection

0: All parameters are allowed to be rewritten

1: Except for the set frequency (F002) and this function code, other function code parameters are prohibited from being rewritten

2: All modifications are prohibited except for this function code

 

 

 

FP02

parameter initialization

0: No action

1: Clear records (FL14~FL19)

2: Restore factory settings (before FL14 F008

Except for FH0O)

1

0

X

 