EPRO PR9268-200-000

EPRO PR9268-200-000

 

Origin: Germany

 

Brand: EPRO

 

Composed of a seismic block and a measuring coil supported by spring plates. The measuring element can move axially in the magnetic field of a circular permanent magnet. When the sensor housing vibrates, a voltage signal proportional to the vibration speed will be generated

 

We have a large amount of inventory in our warehouse. Welcome to inquire online about any model and quantity, with discounted prices.

24-hour service for you

Category:
Share

Related products

 
 

Product Introduction

Product Features 
Accurate measurement: It can accurately measure mechanical vibrations in the frequency range of 4Hz-1000Hz and 10Hz-1000Hz, with a maximum amplitude measurement of 2mm-3mm (peak to peak).
Strong anti-interference ability: The measuring coil has the characteristics of high output and low impedance, which makes the sensor have strong anti-interference ability.
Good environmental adaptability: The sturdy structure allows installation in hazardous environments, with a working temperature of up to 200 ° C and a waterproof protection level of IP55 or IP65.
Diverse Sensitivity: There are three different sensitivities to choose from to meet different measurement needs.


technical parameter
Output signal: Voltage signal 457 proportional to vibration speed.
Measurement range: The amplitude can reach 2mm-3mm (peak to peak) 57.
Frequency range: 4Hz-1000Hz and 10Hz-1000Hz457.
Natural frequency: 4Hz-13Hz45.
Application areas: Suitable for vibration measurement of various turbomachinery, fans, compressors, gearboxes, water pumps, coal mills and other equipment, and can be directly connected to the MMS3000 and MMS6000 turbine monitoring and protection systems produced by epro company.


Installation precautions 
The 6th terminal in the Haring connector of PR9268 is the shield of the probe and should be connected to the protective ground inside the cabinet; The fifth terminal is connected to the outer shell of the probe and is no longer connected to the protective ground inside the cabinet to prevent the formation of double ended grounding and interference signals from entering.
For some eddy current sensors with 1-meter connectors, the LEMO connector must be insulated with heat shrink tubing to ensure insulation between the LEMO connector and the metal tube and cable armor, preventing interference signals from entering.

 

Many products are not yet on the shelves please contact us for more products.

 

If there is inconsistency between the product model and the display picture, the model shall prevail, please contact us for specific product pictures, we will

arrange to take pictures in the warehouse to confirm!

 

Technical Team Service Hotline

 

csyili980622@gmail.com  +86 13306931261

 

wujinghan102@gmail.com +8613376990653

  • 返回顶部