Commissioning parameters of Mitsubishi frequency converter uncoiler

Author: zhddq
Published on: 2025-03-14
Category: Industry News

The sensor adopts 0-10V three wire voltage signal, of which the terminals are 10, 5 and 4. It sends the signal to the frequency converter to control the speed of the motor and realize stable uncoiling and paying off. The uncoiler has negative effect and the winder has positive effect. The frequency converter model is fr-a740-2.2k

Equipment parameters

Parameter number

name

set up

Remarks

PR79

Operation mode

2

External control mode

PR1

Upper limit frequency

50

 

PR2

Lower limit frequency

0

 

PR3

Reference frequency

50

Set the frequency of the rated torque of the motor

PR7

Acceleration time

1

 

PR8

Deceleration time

1

 

PR9

Electronic overcurrent protection

0

 

PR0

Increase starting torque

6%

It can be adjusted without adjustment. It can be adjusted when the load is large

PR125

Change the maximum value of potentiometer

52

Maximum frequency of potentiometer

PR83

Rated voltage of motor

400

 

PR84

Rated frequency of motor

50

 

PR82

Motor excitation current

 

 

PR80

Motor capacity

0.4KW

 

PR192

ABC terminal function selection

0

Inverter operation

PR160

Display basic and extended parameters

0

 

PR77

Allow to modify all energy

2

 

Method of restoring factory settings: switch the operation mode to Pu mode, press "pu/ext" to switch, press mode to switch to P.0, then turn the button to switch to ALLC, change the parameter to 1, and power on again (see page p48 of fa-700 user manual for details)
Set the parameters: pr79 to 3 and pr161 to 1 to use the knob as a potentiometer