• 2025-01-24
    1. KSS00276 robot parameters are not equal to robot type   ① Login Expert Mode   ② Teaching pendant operation: [Menu] - [Display] - [Variables] - [Single]   ③ $ROBTRAFO [] new value: TRAFONAME[]   ④ Click on 'Set Values'.   2. Battery alarm: ① "Rechargeable battery warning - an aging battery was found, but the battery is not functioning properly   The quantity is still sufficient   ② Unable to cache   Analysis: This situation usually occurs when the robot is first turned on, and the battery plug is not plugged into the CCU board in the control cabinet when the robot leaves the factory.   Measure: Find the battery power plug inside the control cabinet and plug it into the CCU card socket corresponding to the label.   3.  KSS00203- Fully operational and open   Measures: ① U...
  • 2025-01-16
    Variable Frequency Drive System is a power electronic device system used to control the speed and output frequency of AC motors. It changes the frequency and  voltage of the input power supply   Control the speed and output power of the motor to meet precise control under different load requirements and operating conditions.   The hardware of the frequency converter system mainly includes the following components:   Inverter host: The inverter host is the core equipment responsible for controlling the speed and output frequency of the motor. It typically includes digital signal  processors (DSP) or microprocessors, power electronics, input/output interfaces, etc.   Rectification device: The rectification device converts AC power into DC power and provides power to the inverter host. It usually includes components such as  rectifier...
  • 2025-01-14
    1、 Voltage measurement method: Measuring voltage is the basic method for repairing industrial touch all-in-one machines and is often used in  practice. It mainly measures the working voltage of circuits and components to identify the faulty parts and components   Make a judgment. Voltage measurement can be divided into two categories: measuring AC voltage and measuring DC voltage.   Measuring AC voltage is to use the AC voltage value of a multimeter to measure the AC voltage value of the industrial touch all-in-one machine  power supply. Of course, a capacitor with a sufficient withstand voltage of around 0.1 μ F can also be connected in series to the multimeter for  measurement   The AC part of the field scanning output circuit, line scanning output circuit, video amplification circuit, and other components. Use a multimeter  ...
  • 2025-01-13
    Torque sensors, also known as torque sensors, torque sensors, torque meters, are divided into two categories: dynamic and static. Among them, dynamic torque sensors can also be called torque sensors, torque speed sensors, non-contact torque sensors, etc Rotating torque sensors, etc. A torque sensor is a device that detects the perception of torsional torque on various rotating or non rotating mechanical components. The torque sensor converts the physical changes in torque into precise electrical signals. Torque sensors can be applied in the manufacturing of viscometers Electric (pneumatic, hydraulic) torque wrenches have the advantages of high precision, fast frequency response, good reliability, and long service life.   A torque sensor is a precision measuring instrument that measures various torques, rotational speeds, and mechanical power. The application scope is very w...
  • 2025-01-10
    With the development of intelligent manufacturing and IoT technology, industrial sensors have become the infrastructure for industrial automation and intelligent  manufacturing. Industrial sensors can achieve real-time monitoring and control on the production line by collecting and transmitting various information, which  helps improve production efficiency, reduce costs, and ensure product quality. So how can we better achieve data collection for industrial sensors?   1. Choose the appropriate sensor   Firstly, we need to choose the appropriate sensor. When selecting sensors, factors such as measurement range, accuracy, sensitivity, stability, anti-interference ability,  and usage environment need to be considered. At the same time, in order to reduce costs and complexity, multi-sensor modules with multiple functions should be  selected to integrat...
  • 2025-01-09
    Valves are control components in fluid transportation systems, with functions such as cutoff, regulation,  diversion, prevention of backflow, stabilization, diversion, or overflow pressure relief. Valves used in fluid  control systems have a wide variety of varieties and specifications, from the simplest globe valves to various  valves used in extremely complex self-control systems. Valves can be used to control the flow of various types  of fluids such as air, water, steam, various corrosive media, mud, oil, liquid metals, and radioactive media. It is  commonly used on ships to control fluids such as compressed air, cooling water, hydraulic oil, etc.   1、 Classification of valves   There are many types of valves, and there are multiple classification methods. They are generally divided  into:   1. Cut off valves: mainly used to cut o...
  • 2025-01-08
    High voltage frequency converters are commonly used in the industrial field, suitable for applications with high power and high voltage (usually exceeding 1kV).  They can provide high output power and carrying capacity, suitable for driving large motors, generator sets, and other high-power equipment. The circuit design  and control system of high-voltage frequency converters are usually more complex to meet the requirements of high voltage and high current.   Low voltage frequency converters are suitable for applications with low voltage (usually below 1kV) and are widely used in household appliances, small mechanical  equipment, air conditioning, etc. They typically provide lower output power and are suitable for speed regulation and control of low-power devices. Low voltage  frequency converters are smaller, cheaper, and easier to operate and maintain ...
  • 2025-01-07
    In PLC applications, it is not recommended to directly connect the alarm to the output terminal, especially in safety alarm and emergency handling situations.  PLC output modules are divided into relay output type and transistor output type. The former is suitable for driving high-power loads, while the latter is not suitable.  The working current and voltage of the alarm are relatively high, and direct connection may damage the PLC or cause safety issues. When using a relay output PLC,  the alarm can be connected to the output terminal, but attention should be paid to independent power supply, reasonable control signal, reliable reset operation,  and alarm safety performance. When designing an alarm system, appropriate solutions should be selected based on the PLC output type and load characteristics to  ensure system reliability. In the app...